<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://wiki.staging.zoneminder.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Doisneau</id>
	<title>ZoneMinder Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="http://wiki.staging.zoneminder.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Doisneau"/>
	<link rel="alternate" type="text/html" href="http://wiki.staging.zoneminder.com/Special:Contributions/Doisneau"/>
	<updated>2026-04-20T05:12:20Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.37.1</generator>
	<entry>
		<id>http://wiki.staging.zoneminder.com/index.php?title=Foscam_FI9821W_V2&amp;diff=15960</id>
		<title>Foscam FI9821W V2</title>
		<link rel="alternate" type="text/html" href="http://wiki.staging.zoneminder.com/index.php?title=Foscam_FI9821W_V2&amp;diff=15960"/>
		<updated>2020-03-07T10:20:16Z</updated>

		<summary type="html">&lt;p&gt;Doisneau: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;= Foscam FI9821W V2 with control =&lt;br /&gt;
&lt;br /&gt;
With the newer version of the Foscam firmware you are prompted to change the default login. I did this then added another user called admin. I&amp;#039;m not sure if this is necessary but I was able to get the camera to work with control.&lt;br /&gt;
&lt;br /&gt;
== Camera Video Settings ==&lt;br /&gt;
&lt;br /&gt;
* Stream Type: HD Mode&lt;br /&gt;
* Resolution: 720P&lt;br /&gt;
* Bit Rate: 128K&lt;br /&gt;
* Frame Rate: 5&lt;br /&gt;
* Key Frame Interval: 50&lt;br /&gt;
* Variable bitrate: Yes&lt;br /&gt;
&lt;br /&gt;
== Zoneminder Monitor Settings ==&lt;br /&gt;
&lt;br /&gt;
* Source Type: Ffmpeg&lt;br /&gt;
* Function: Modect (or your choice)&lt;br /&gt;
* Source Path: rtsp://admin:(Password)@IP-Address:88/videoMain&lt;br /&gt;
* Remote Method: RTP/Unicast&lt;br /&gt;
* Capture Resolution (pixels): &amp;lt;code&amp;gt;1280x720 720p&amp;lt;/code&amp;gt; preset&lt;br /&gt;
* Control Type: Foscam FI9821W (see note 1)&lt;br /&gt;
* Control Device: (Password)     (see note 2)&lt;br /&gt;
* Control Address: IP-Address:88&lt;br /&gt;
* Auto Stop Timeout: 1&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&lt;br /&gt;
Note 1: Edit Foscam FI9821W and remove check marks in Zoom, Focus, White, Iris, and change Presets number from 16 to 8&lt;br /&gt;
&lt;br /&gt;
Note 2: You may be able to use just the camera password or user=(user)&amp;amp;pwd=(password)&lt;br /&gt;
&lt;br /&gt;
Note 2 addendum: I was only able to PTZ working if Control Device was in the format of user:password&lt;br /&gt;
&lt;br /&gt;
=== Resolution ===&lt;br /&gt;
&lt;br /&gt;
You should be able to use higher or lower resolutions but keep the WidthxHeight ratio within the values you did set in the Camera settings.&lt;br /&gt;
&lt;br /&gt;
If those settings are not equal, your ZM logs will complain: &amp;lt;code&amp;gt;Monitor dimensions are 640x400 but camera is sending 1280x720&amp;lt;/code&amp;gt;&lt;/div&gt;</summary>
		<author><name>Doisneau</name></author>
	</entry>
	<entry>
		<id>http://wiki.staging.zoneminder.com/index.php?title=Foscam_FI9821W_V2&amp;diff=15959</id>
		<title>Foscam FI9821W V2</title>
		<link rel="alternate" type="text/html" href="http://wiki.staging.zoneminder.com/index.php?title=Foscam_FI9821W_V2&amp;diff=15959"/>
		<updated>2020-03-07T10:17:52Z</updated>

		<summary type="html">&lt;p&gt;Doisneau: Camera resolution should reflect what has been set into the camera itself&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;= Foscam FI9821W V2 with control =&lt;br /&gt;
&lt;br /&gt;
With the newer version of the Foscam firmware you are prompted to change the default login. I did this then added another user called admin. I&amp;#039;m not sure if this is necessary but I was able to get the camera to work with control.&lt;br /&gt;
&lt;br /&gt;
== Camera Video Settings ==&lt;br /&gt;
&lt;br /&gt;
* Stream Type: HD Mode&lt;br /&gt;
* Resolution: 720P&lt;br /&gt;
* Bit Rate: 128K&lt;br /&gt;
* Frame Rate: 5&lt;br /&gt;
* Key Frame Interval: 50&lt;br /&gt;
* Variable bitrate: Yes&lt;br /&gt;
&lt;br /&gt;
== Zoneminder Monitor Settings ==&lt;br /&gt;
&lt;br /&gt;
* Source Type: Ffmpeg&lt;br /&gt;
* Function: Modect (or your choice)&lt;br /&gt;
* Source Path: rtsp://admin:(Password)@IP-Address:88/videoMain&lt;br /&gt;
* Remote Method: RTP/Unicast&lt;br /&gt;
* Capture Resolution (pixels): &amp;lt;code&amp;gt;1280x720 720p&amp;lt;/code&amp;gt; preset&lt;br /&gt;
* Control Type: Foscam FI9821W (see note 1)&lt;br /&gt;
* Control Device: (Password)     (see note 2)&lt;br /&gt;
* Control Address: IP-Address:88&lt;br /&gt;
* Auto Stop Timeout: 1&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&lt;br /&gt;
Note 1: Edit Foscam FI9821W and remove check marks in Zoom, Focus, White, Iris, and change Presets number from 16 to 8&lt;br /&gt;
&lt;br /&gt;
Note 2: You may be able to use just the camera password or user=(user)&amp;amp;pwd=(password)&lt;br /&gt;
&lt;br /&gt;
Note 2 addendum: I was only able to PTZ working if Control Device was in the format of user:password&lt;br /&gt;
&lt;br /&gt;
You should be able to use higher or lower resolutions but keep the WidthxHeight ratio within the values you did set in the Camera settings.&lt;/div&gt;</summary>
		<author><name>Doisneau</name></author>
	</entry>
	<entry>
		<id>http://wiki.staging.zoneminder.com/index.php?title=Foscam_FI9821W_V2&amp;diff=15958</id>
		<title>Foscam FI9821W V2</title>
		<link rel="alternate" type="text/html" href="http://wiki.staging.zoneminder.com/index.php?title=Foscam_FI9821W_V2&amp;diff=15958"/>
		<updated>2020-03-07T10:09:49Z</updated>

		<summary type="html">&lt;p&gt;Doisneau: basic formatting&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;= Foscam FI9821W V2 with control =&lt;br /&gt;
&lt;br /&gt;
With the newer version of the Foscam firmware you are prompted to change the default login. I did this then added another user called admin. I&amp;#039;m not sure if this is necessary but I was able to get the camera to work with control.&lt;br /&gt;
&lt;br /&gt;
== Camera Video Settings ==&lt;br /&gt;
&lt;br /&gt;
* Stream Type: HD Mode&lt;br /&gt;
* Resolution: 720P&lt;br /&gt;
* Bit Rate: 128K&lt;br /&gt;
* Frame Rate: 5&lt;br /&gt;
* Key Frame Interval: 50&lt;br /&gt;
* Variable bitrate: Yes&lt;br /&gt;
&lt;br /&gt;
== Zoneminder Monitor Settings ==&lt;br /&gt;
&lt;br /&gt;
* Source Type: Ffmpeg&lt;br /&gt;
* Function: Modect (or your choice)&lt;br /&gt;
* Source Path: rtsp://admin:(Password)@IP-Address:88/videoMain&lt;br /&gt;
* Remote Method: RTP/Unicast&lt;br /&gt;
* Capture Width: 640&lt;br /&gt;
* Capture Height: 320&lt;br /&gt;
* Control Type: Foscam FI9821W (see note 1)&lt;br /&gt;
* Control Device: (Password)     (see note 2)&lt;br /&gt;
* Control Address: IP-Address:88&lt;br /&gt;
* Auto Stop Timeout: 1&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&lt;br /&gt;
Note 1: Edit Foscam FI9821W and remove check marks in Zoom, Focus, White, Iris, and change Presets number from 16 to 8&lt;br /&gt;
&lt;br /&gt;
Note 2: You may be able to use just the camera password or user=(user)&amp;amp;pwd=(password)&lt;br /&gt;
&lt;br /&gt;
Note 2 addendum: I was only able to PTZ working if Control Device was in the format of user:password&lt;br /&gt;
&lt;br /&gt;
You should be able to use higher or lower resolutions but keep the WidthxHeight ratio within the 640x320 value&lt;/div&gt;</summary>