	<entry>
		<id>http://wiki.staging.zoneminder.com/index.php?title=ACTi&amp;diff=16903</id>
		<title>ACTi</title>
		<link rel="alternate" type="text/html" href="http://wiki.staging.zoneminder.com/index.php?title=ACTi&amp;diff=16903"/>
		<updated>2023-01-21T03:52:14Z</updated>

		<summary type="html">&lt;p&gt;Novarlynx: Added RTSP settings for ACTI ACM cameras, such as my ACM 3401s.&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
== ACM 5611 ==&lt;br /&gt;
&lt;br /&gt;
This is the setup I am using for the ACM 5611&lt;br /&gt;
&lt;br /&gt;
Source type = remote&lt;br /&gt;
&lt;br /&gt;
Remote Protocol = HTTP&lt;br /&gt;
&lt;br /&gt;
Remote Method = Simple&lt;br /&gt;
&lt;br /&gt;
Remote Host Name = login:pwd@IP_address&lt;br /&gt;
&lt;br /&gt;
Remote Port = 80&lt;br /&gt;
&lt;br /&gt;
Remote Host Path = /cgi-bin/cmd/encoder?GET_STREAM&lt;br /&gt;
&lt;br /&gt;
Remote Image Colours = 24 bit colour&lt;br /&gt;
&lt;br /&gt;
Capture Width        1280&lt;br /&gt;
&lt;br /&gt;
Capture Height        720 (also used 1024)&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Those were all I set and it came right up.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
I have used this same format with other cameras of the&lt;br /&gt;
&lt;br /&gt;
ACM family, they all worked.&lt;br /&gt;
&lt;br /&gt;
== ACTi ACM 3401 (RTSP), works for other ACM series cameras ==&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;In ACTI camera video settings:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Streaming Method = RTP Over UDP&lt;br /&gt;
&lt;br /&gt;
RTSP Authen Enable: checked&lt;br /&gt;
&lt;br /&gt;
B2 Frame Enable: unchecked (Important!)&lt;br /&gt;
&lt;br /&gt;
Strongly recommend changing Root password (User Account screen) from default!&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;In ZM Monitor config&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
Source type = Remote&lt;br /&gt;
&lt;br /&gt;
Protocol = RTSP&lt;br /&gt;
&lt;br /&gt;
Method = RTSP/Unicast&lt;br /&gt;
&lt;br /&gt;
Host Name = user:pass@address (default user:pass = admin:123456)&lt;br /&gt;
&lt;br /&gt;
Port = 7070 (camera&amp;#039;s default)&lt;br /&gt;
&lt;br /&gt;
Path = leave blank&lt;br /&gt;
&lt;br /&gt;
Target colourspace = 24 bit colour&lt;br /&gt;
&lt;br /&gt;
Capture Resolution = 1280 x 1024 (or whatever your camera is set to)&lt;br /&gt;
&lt;br /&gt;
Preserve aspect ratio: unchecked&lt;br /&gt;
&lt;br /&gt;
== ACTi D32 ==&lt;br /&gt;
&lt;br /&gt;
HTTP support buggy in the D32. Use RTSP.&lt;br /&gt;
&lt;br /&gt;
Remote Method: RTP/RTSP&lt;br /&gt;
&lt;br /&gt;
Remote host name: user:pass@host&lt;br /&gt;
&lt;br /&gt;
Remote Host Port: 7070 (this is the default port for the factory configuration. can be changed in Network menu)&lt;br /&gt;
&lt;br /&gt;
Remote Host Path: (leave empty)&lt;br /&gt;
&lt;br /&gt;
Target Colorspace 24 bit color&lt;br /&gt;
&lt;br /&gt;
Capture Width: (set the same as camera&amp;#039;s config)&lt;br /&gt;
&lt;br /&gt;
Capture Height: (set the same as camera&amp;#039;s config)&lt;br /&gt;
&lt;br /&gt;
Preserve Aspect Ratio: unchecked&lt;br /&gt;
&lt;br /&gt;
Orientation: (set to whatever you need/like)&lt;br /&gt;
&lt;br /&gt;
Deinterlacing: Disabled&lt;br /&gt;
&lt;br /&gt;
== ACTi TCM-5611 working setup ==&lt;br /&gt;
&lt;br /&gt;
I could only get the streaming unicast from the camera working with VLC but not with Zoneminder so I went the HTTP route.&lt;br /&gt;
&lt;br /&gt;
Using the camera&amp;#039;s web configurator page, I first set the camera to 640x480, MJPEG.&lt;br /&gt;
&lt;br /&gt;
Then created a device in Zoneminder.&lt;br /&gt;
&lt;br /&gt;
Source:  remote&lt;br /&gt;
&lt;br /&gt;
protocol: HTTP&lt;br /&gt;
&lt;br /&gt;
FPS:     blank&lt;br /&gt;
&lt;br /&gt;
max FPS: blank&lt;br /&gt;
&lt;br /&gt;
640x480&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
address:  user:password@xxx.xxx.xxx.xxx&lt;br /&gt;
&lt;br /&gt;
path:     /cgi-bin/cmd/system?GET_STREAM&lt;br /&gt;
&lt;br /&gt;
=== RTP B2 Frames ===&lt;br /&gt;
&lt;br /&gt;
Some ACTi cameras, including the KCM-5611 and B95, have a proprietary feature which injects &amp;quot;B2 Frames&amp;quot; (an ACTi-proprietary data blob containing timestamps and other info) into the MJPEG stream. If this feature is enabled, neither ZoneMinder nor browsers like Firefox and Chrome will be able to decode the MJPEG stream from the camera. On some cameras this option is enabled by default; to disable the B2 frames, go to the Network-&amp;gt;RTP page in the camera&amp;#039;s Web Configurator and un-check the RTP B2 Frame option.&lt;/div&gt;</summary>