Difference between revisions of "Revotech I706-P"

From ZoneMinder Wiki
Jump to navigationJump to search
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
=Dimensions=
=Dimensions=
 
[[File:Revotech_I706-P.png|400px|thumb|left|alt text]]


=Revotech I706-P camera setup=
=Revotech I706-P camera setup=
* POE Mini Indoor 2304 x 1296 3.0MP ONVIF H.265 H.264
* POE Mini Indoor 2304 x 1296 3.0MP ONVIF H.265 H.264
* no proprietary software and/or app from vendor required (also no IE required) to setup when following this procedure '''(camera default is NOT set to DHCP !!!)'''
* no proprietary software and/or app from vendor required (also no IE required) to setup when following this procedure '''(camera default is NOT set to DHCP !!!)'''
** connect camera to POE switch
# connect camera to POE switch
** connect notebook to same POE switch and set static IP address of notebook to 192.1681.2
# connect notebook to same POE switch and set static IP address of notebook to 192.1681.2
** use "arp -a" to find camera IP address (mine was 192.168.1.105, network 192.168.1.0/24 seems to be default for this camera)
# use "arp -a" to find camera IP address (mine was 192.168.1.105, network 192.168.1.0/24 seems to be default for this camera)
** open URL http://192.168.1.105 and login to camera web console (default user is admin and no password)
# open URL http://192.168.1.105 and login to camera web console (default user is admin and no password)
** set password
# set password
** activate DHCP in Network/Basic menu (I've disabled all other options) - you may also use a static IP address
# activate DHCP in Network/Basic menu (I've disabled all other options) - you may also use a static IP address
** reconnect camera to your usual network
# '''Set Video Codec to H264 to be able to playback recorded streams in usual web browsers!''' (default is H265 in camera!)
** find camera's new IP address in your router
# reconnect camera to your usual network
** set a fix IP address for camera's MAC in your routers DHCP settings '''and for security block camera from internet access (it will try to access some external servers!)'''
# find camera's new IP address in your router
# set a fix IP address for camera's MAC in your routers DHCP settings '''and for security block camera from internet access (it will try to access some external servers!)'''


=Settings in ZoneMinder 1.36.1=
=Settings in ZoneMinder 1.36.1=
* leave all default but
* leave all default but
** Source Path for 2304 x 1296: rtsp://username:password@ip_address:8554/live0.265
# Source Path for 2304 x 1296: rtsp://username:password@ip_address:8554/live0.264
** Source Path for  704 x  576: rtsp://username:password@ip_address:8554/live1.265
# Source Path for  704 x  576: rtsp://username:password@ip_address:8554/live1.264
* camera has no audio and no PTZ
* camera has no audio and no PTZ

Latest revision as of 16:15, 20 June 2021

Dimensions

alt text

Revotech I706-P camera setup

  • POE Mini Indoor 2304 x 1296 3.0MP ONVIF H.265 H.264
  • no proprietary software and/or app from vendor required (also no IE required) to setup when following this procedure (camera default is NOT set to DHCP !!!)
  1. connect camera to POE switch
  2. connect notebook to same POE switch and set static IP address of notebook to 192.1681.2
  3. use "arp -a" to find camera IP address (mine was 192.168.1.105, network 192.168.1.0/24 seems to be default for this camera)
  4. open URL http://192.168.1.105 and login to camera web console (default user is admin and no password)
  5. set password
  6. activate DHCP in Network/Basic menu (I've disabled all other options) - you may also use a static IP address
  7. Set Video Codec to H264 to be able to playback recorded streams in usual web browsers! (default is H265 in camera!)
  8. reconnect camera to your usual network
  9. find camera's new IP address in your router
  10. set a fix IP address for camera's MAC in your routers DHCP settings and for security block camera from internet access (it will try to access some external servers!)

Settings in ZoneMinder 1.36.1

  • leave all default but
  1. Source Path for 2304 x 1296: rtsp://username:password@ip_address:8554/live0.264
  2. Source Path for 704 x 576: rtsp://username:password@ip_address:8554/live1.264
  • camera has no audio and no PTZ