Difference between revisions of "Panasonic"
(Rename the Notes section to Authentication because it applies to all models.) |
(Add troubleshooting section.) |
||
Line 160: | Line 160: | ||
=Authentication= | =Authentication= | ||
If the camera requires a username and password, then put the credentials in the '''Remote Host Name''' field on the ''Monitor -> Source'' tab for the camera in ZoneMinder like this: | If the camera requires a username and password, then put the credentials in the '''Remote Host Name''' field on the ''Monitor -> Source'' tab for the camera in ZoneMinder like this: | ||
Line 181: | Line 175: | ||
The username and password are separated by one colon character, which are separated from the IP address or host name by the 'at' symbol. | The username and password are separated by one colon character, which are separated from the IP address or host name by the 'at' symbol. | ||
=Troubleshooting= | |||
* Using the anonymous guest account with default permissions, or using incorrect credentials, will result in a black box or this error in the zmdc.log file: | |||
zmdc.ERR ['zmc -m 1' exited abnormally, exit status 255] | |||
* Remember to grant all permissions to the ZoneMinder account in the camera and double check the spelling of the username and password. ZoneMinder does not log a sensible error message if the access privileges or credentials are incorrect, it just crashes. | |||
* Use the VideoLAN player to test RTSP like this: | |||
vlc rtsp://192.168.0.254/nphMpeg4/nil-640x480 | |||
If VLC cannot play the stream, then ZoneMinder cannot record it. (Many other RTSP players are incompatible with Panasonic network cameras. Use VLC.) | |||
=External Resources= | =External Resources= |
Revision as of 15:52, 2 December 2011
All members of the BL and BB model families are likely to be compatible, including PTZ support. The "Panasonic IP" monitor preset in ZoneMinder is known to be compatible with these Panasonic netcam models:
- BL-C1A, BL-C1CN, BL-C1E
- BL-C20A, BL-C20CN, BL-C20E
- BL-C30A, BL-C30CN, BL-C30E
- BL-C101A, BL-C101CN, BL-C101E
- BL-C111A, BL-C111CN, BL-C111E
- BL-C121A, BL-C121CN, BL-C121E
- BL-C131A, BL-C131CN, BL-C131E
- BL-C140A, BL-C140CN, BL-C140E
- BL-C160A, BL-C160CN, BL-C160E
- BB-HCM381A, BB-HCM381CN, BB-HCM381E
- BB-HCM511A, BB-HCM511CN, BB-HCM511E
- BB-HCM527A, BB-HCM527CN, BB-HCM527E
- BB-HCM531A, BB-HCM531CN, BB-HCM531E
- BB-HCM547A, BB-HCM547CN, BB-HCM547E
- BB-HCM580A, BB-HCM580CN, BB-HCM580E
- BB-HCM581A, BB-HCM581CN, BB-HCM581E
- KX-HCM10
Initial Hardware Setup
- The camera uses a default IP address of 192.168.0.254 if it does not get a DHCP lease. Many firmware revisions ship with DHCP disabled by default. If you are not using the configuration utility for Microsoft Windows, then you may need to do something like `sudo ifconfig eth0:0 192.168.0.2` at a terminal prompt to access the camera and enable DHCP.
- Upgrade the firmware. ZoneMinder 1.25 expects the latest firmware release.
- Enable the guest account:
- Click Setup in the top menu.
- Click Administrator in the side menu.
- Choose Permit access from guest users.
- Click the Save button.
- Set privileges on the guest account for ZoneMinder:
- Click Setup in the top menu.
- Click General User in the side menu.
- Choose Guest User in the menu.
- Click the Modify button.
- Change Video Display Time to Unlimited.
- Enable all Access Level checkboxes.
- Click the Save button.
Only set access credentials on Panasonic equipment after you have a working ZoneMinder configuration. ZoneMinder handles network camera authentication very poorly, which can cause frustrating problems like the "white screen" error, the "blue screen" error, "exit 255" crashes, or segmentation faults.
MJPEG Configuration
Example
At the Monitor -> Source page for the camera:
Remote Protocol: HTTP Remote Method: Simple Remote Host Name: 192.168.1.254 Remote Host Port: 80 Remote Host Path: nphMotionJpeg?Resolution=640x480&Quality=Standard Remote Image Colors: 24 bit color Capture Width (pixels): 640 Capture Height (pixels): 480 Preserve Aspect Ratio: Off Orientation: Normal
Example for Old Firmware
Change nphMotionJpeg to nphContinuousServerPush or cgi-bin/nphContinuousServerPush if the camera has old firmware like this:
Remote Host Path: cgi-bin/nphContinuousServerPush?Resolution=640x480&Quality=Standard
Cameras models that only have the old firmware interface are:
- BL-C20A
Parameters
The required Quality CGI parameter sets JPEG quality and can be one of Clarity, Standard, or Motion.
The required Resolution CGI parameter can be one of 1280x1024, 640x480, 320x240, or 160x120 pixels.
Note: Only hi-def models support the 1280x1024 resolution, and some low end models like the Panasonic BL-C1A Petcam do not support the 640x480 resolution.
MJPEG Frame Size | Quality=Clarity | Quality=Standard | Quality=Motion |
---|---|---|---|
Resolution=1280x1024 | ? | ? | ? |
Resolution=640x480 | 50kB | 30kB | 20kb |
Resolution=320x240 | 25kB | 15kB | 8kB |
Resolution=160x120 | 8kB | 5kB | 3kB |
The optional Framerate parameter can be 0.1 through 30.00 frames per second in one-tenth increments. For example, to take an image every other second:
Remote Host Path: nphMotionJpeg?Resolution=640x480&Quality=Standard&Framerate=0.5
Performance
In MJPEG mode, ZoneMinder can sustain approximately 5 fps from a Panasonic netcam. In ideal conditions the maximum is approximately 25 fps.
On busy systems, ZoneMinder performs better if the frame rate is externally limited at the camera. For example, to limit capture to 10 fps, set:
Remote Host Path: nphMotionJpeg?Resolution=640x480&Quality=Standard&Framerate=10
On the Monitor -> General configuration page for the camera in ZoneMinder, leave the Maximum FPS field empty.
RTSP/MPEG4 Configuration
Note: Low end models like the Panasonic BL-C1A Petcam only support MJPEG because they do not have an MPEG4 encoder.
Example
At the Monitor -> Source page for the camera:
Remote Protocol: RTSP Remote Method: RTP/Unicast Remote Host Name: 192.168.1.254 Remote Host Port: 554 Remote Host Path: nphMpeg4/g726-640x480 Remote Image Colors: 24 bitcolor Capture Width (pixels): 640 Capture Height (pixels): 480 Preserve Aspect Ratio: Off Orientation: Normal
Parameters
Audio can be disabled on models that have it by changing g726 to nil like this:
Remote Host Path: nphMpeg4/nil-640x480
Available resolutions are:
Remote Host Path: nphMpeg4/g726-160x120 Remote Host Path: nphMpeg4/g726-320x240 Remote Host Path: nphMpeg4/g726-640x480 Remote Host Path: nphMpeg4/g726-1280x1024
Note: Only high definition models support the 1280x1024 resolution.
Performance
In RTSP mode, ZoneMinder can get 30 fps from a Panasonic netcam that has an MPEG4 encoder. The raw idle RTP output of a quiet scene for these cameras is approximately 400 kbps, or 5GB per day.
To force a particular MPEG4 quality, set the minimum and maximum bitrates to the same value on the "Setup -> Video Streaming" tab of the web interface built-into the camera.
ZoneMinder transcodes the MPEG4 stream to add a banner or stream through the web interface. Doing this on one 640x480@30fps stream can consume an entire core on a modern CPU. If the CPU becomes overloaded, then the zmc process will crash and the Feed Watch page will be blank or show the broken image icon. An easy way to reduce CPU load is to set the "Maximum FPS" field on the monitor General tab to 15 or less.
Authentication
If the camera requires a username and password, then put the credentials in the Remote Host Name field on the Monitor -> Source tab for the camera in ZoneMinder like this:
Remote Protocol: HTTP Remote Method: Simple Remote Host Name: MyUser:MyPass@192.168.1.254 Remote Host Port: 80 Remote Host Path: /nphMotionJpeg?Resolution=640x480&Quality=Standard Remote Image Colors: 24 bit color Capture Width (pixels): 640 Capture Height (pixels): 480 Preserve Aspect Ratio: Off Orientation: Normal
The username and password are separated by one colon character, which are separated from the IP address or host name by the 'at' symbol.
Troubleshooting
- Using the anonymous guest account with default permissions, or using incorrect credentials, will result in a black box or this error in the zmdc.log file:
zmdc.ERR ['zmc -m 1' exited abnormally, exit status 255]
- Remember to grant all permissions to the ZoneMinder account in the camera and double check the spelling of the username and password. ZoneMinder does not log a sensible error message if the access privileges or credentials are incorrect, it just crashes.
- Use the VideoLAN player to test RTSP like this:
vlc rtsp://192.168.0.254/nphMpeg4/nil-640x480
If VLC cannot play the stream, then ZoneMinder cannot record it. (Many other RTSP players are incompatible with Panasonic network cameras. Use VLC.)