Difference between revisions of "Airlink 101"
m (Reordering page details, minor link and info tweaks) |
|||
(5 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
== AIC250W == | == AIC250W == | ||
Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = / | Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /image.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration. | ||
AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200 | AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200 | ||
== AICN747/AICN747W (Airlink101 SkyIPCam 747W) == | == AICN747/AICN747W (Airlink101 SkyIPCam 747W) == | ||
Line 57: | Line 56: | ||
[[Category:Cameras]] | [[Category:Cameras]] | ||
[[Category:Network Cameras]] | |||
== AICN1620W == | |||
JPEG stills | |||
<IP_ADDRESS>/cgi/jpg/image.cgi | |||
MJPEG | |||
<IP_ADDRESS>/cgi/mjpg/mjpg.cgi | |||
Remote Protocol: HTTP | |||
Remote Method: Simple | |||
Remote Host Name: <username>:<password>@<ip of camera> | |||
Remote Host Port: 80 | |||
Remote Host Path: /cgi/mjpg/mjpg.cgi | |||
Remote Image colors: 24 bit | |||
Capture Width: 320 | |||
Capture Height: 240 | |||
you also have to change a setting in the camera setup>video>mpeg4>QVGA and setup>video>mjpeg>QVGA | |||
For Zoneminder this will work but I wouldnt recommend. There is a very long lag time before the camera sees an image and it is shown on Zoneminder. It has taken up too 1 minute before i have seen change in the camera feed. |
Latest revision as of 12:31, 27 January 2012
AIC250W
Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /image.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration.
AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200
AICN747/AICN747W (Airlink101 SkyIPCam 747W)
Same Camera as Fitivision CS-130A/CS-131A and TrendNet TV-IP410/TV-IP410W. The 'W'/CS-131A version is wireless. Note: the Trendnet cameras have no built-in IR illumination.
The device requires authentication, so you need to provide the Remote Host Name parameter with hostname = <username>:<password>@<ip of camera> path = /cgi/jpg/image.cgi for JPEG stills, or /cgi/mjpg/mjpg.cgi for MJPEG (MJPEG mode requires firmware v1.0.0-24 or later)
Remote Protocol: HTTP
Remote Method: Simple
Remote Host Name: <username>:<password>@<ip of camera>
Remote Host Port: 80
Remote Host Path: /cgi/mjpg/mjpg.cgi
Remote Image colors: 24 bit
Capture Width: 640
Capture Height: 480
- SkyIPCam 7xx PTZ module for ZM and example audio push/dump scripts
- Additional info on the AirLink SkyIPCam 747W
Airlink Skyipcam777w
Remote Protocol: HTTP
Remote Method: Simple
Remote Host Name: {username}:{password}@{camera ip}
Remote Host Port: 80
Remote Host Path: /cgi/mjpg/mjpg.cgi
Remote Image colors: 24 bit
Capture Width: 640
Capture Height: 480
AICN1620W
JPEG stills <IP_ADDRESS>/cgi/jpg/image.cgi
MJPEG <IP_ADDRESS>/cgi/mjpg/mjpg.cgi
Remote Protocol: HTTP
Remote Method: Simple
Remote Host Name: <username>:<password>@<ip of camera>
Remote Host Port: 80
Remote Host Path: /cgi/mjpg/mjpg.cgi
Remote Image colors: 24 bit
Capture Width: 320
Capture Height: 240
you also have to change a setting in the camera setup>video>mpeg4>QVGA and setup>video>mjpeg>QVGA
For Zoneminder this will work but I wouldnt recommend. There is a very long lag time before the camera sees an image and it is shown on Zoneminder. It has taken up too 1 minute before i have seen change in the camera feed.