Difference between revisions of "Airlink 101"

From ZoneMinder Wiki
Jump to navigationJump to search
(added page to the 'Network Cameras' category)
 
(3 intermediate revisions by the same user not shown)
Line 57: Line 57:
[[Category:Cameras]]
[[Category:Cameras]]
[[Category:Network Cameras]]
[[Category:Network Cameras]]
== AICN1620W ==
JPEG stills
<IP_ADDRESS>/cgi/jpg/image.cgi
MJPEG
<IP_ADDRESS>/cgi/mjpg/mjpg.cgi
Remote Protocol: HTTP
Remote Method: Simple
Remote Host Name: <username>:<password>@<ip of camera>
Remote Host Port: 80
Remote Host Path: /cgi/mjpg/mjpg.cgi
Remote Image colors: 24 bit
Capture Width: 320
Capture Height: 240
you also have to change a setting in the camera setup>video>mpeg4>QVGA and setup>video>mjpeg>QVGA
For Zoneminder this will work but I wouldnt recommend. There is a very long lag time before the camera sees an image and it is shown on Zoneminder. It has taken up too 1 minute before i have seen change in the camera feed.

Latest revision as of 12:31, 27 January 2012

AIC250W

Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /image.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration.

AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200

AICN747/AICN747W (Airlink101 SkyIPCam 747W)

Same Camera as Fitivision CS-130A/CS-131A and TrendNet TV-IP410/TV-IP410W. The 'W'/CS-131A version is wireless. Note: the Trendnet cameras have no built-in IR illumination.

The device requires authentication, so you need to provide the Remote Host Name parameter with hostname = <username>:<password>@<ip of camera> path = /cgi/jpg/image.cgi for JPEG stills, or /cgi/mjpg/mjpg.cgi for MJPEG (MJPEG mode requires firmware v1.0.0-24 or later)


Remote Protocol: HTTP

Remote Method: Simple

Remote Host Name: <username>:<password>@<ip of camera>

Remote Host Port: 80

Remote Host Path: /cgi/mjpg/mjpg.cgi

Remote Image colors: 24 bit

Capture Width: 640

Capture Height: 480


Airlink Skyipcam777w

Remote Protocol: HTTP

Remote Method: Simple

Remote Host Name: {username}:{password}@{camera ip}

Remote Host Port: 80

Remote Host Path: /cgi/mjpg/mjpg.cgi

Remote Image colors: 24 bit

Capture Width: 640

Capture Height: 480



AICN1620W

JPEG stills <IP_ADDRESS>/cgi/jpg/image.cgi

MJPEG <IP_ADDRESS>/cgi/mjpg/mjpg.cgi


Remote Protocol: HTTP

Remote Method: Simple

Remote Host Name: <username>:<password>@<ip of camera>

Remote Host Port: 80

Remote Host Path: /cgi/mjpg/mjpg.cgi

Remote Image colors: 24 bit

Capture Width: 320

Capture Height: 240

you also have to change a setting in the camera setup>video>mpeg4>QVGA and setup>video>mjpeg>QVGA

For Zoneminder this will work but I wouldnt recommend. There is a very long lag time before the camera sees an image and it is shown on Zoneminder. It has taken up too 1 minute before i have seen change in the camera feed.