Difference between revisions of "Amcrest"
From ZoneMinder Wiki
Jump to navigationJump to search
m (fix image) |
(Added IP2M-841B data for 1.31.44) |
||
Line 61: | Line 61: | ||
Focus-out:/cgi-bin/ptz.cgi?action=start&code=FocusFar&channel=0&arg1=1&arg2=1&arg3=0 | Focus-out:/cgi-bin/ptz.cgi?action=start&code=FocusFar&channel=0&arg1=1&arg2=1&arg3=0 | ||
Stop:/cgi-bin/ptz.cgi?action=stop&code=Right&channel=0&arg1=0&arg2=0&arg3=0&arg4=0 | Stop:/cgi-bin/ptz.cgi?action=stop&code=Right&channel=0&arg1=0&arg2=0&arg3=0&arg4=0 | ||
==ZoneMinder 1.31.44== | |||
===RTSP=== | |||
Tested successfully using: | |||
'''General Settings''' | |||
Source Type: Ffmpeg | |||
'''Source Settings''' | |||
Source Path: | |||
rtsp://[username]:[password]@[deviceIP]:[RSTP Port]/cam/realmonitor?channel=1&subtype=0 | |||
*554 is the default RSTP Port | |||
Method: TCP | |||
Capture Width and Height: set to match the stream (1280x720) | |||
=IP2M-723W= | =IP2M-723W= |
Revision as of 19:33, 24 July 2018
Amcrest is a manufacturer of indoor and outdoor IP cameras as well as DVRs.
IP2M-841B/IP2M-841W
Error creating thumbnail: Unable to save thumbnail to destination
An indoor IP camera with IR Night vision and pan/tilt, this is one of their more prolific models of camera.
ZoneMinder 1.28-1.30.0
RTSP
Tested successfully using:
- ZM 1.28.1, FW 2.420.AC00.11.R
General Settings Source Type: Ffmpeg Source Settings Source Path: For Primary Stream: rtsp://[username]:[password]@[deviceIP]:554/cam/realmonitor?channel=1&subtype=0 For Secondary Stream: rtsp://[username]:[password]@[deviceIP]:554/cam/realmonitor?channel=1&subtype=1 Remote Method: RTP/RTSP Capture Width and Height - set to match the stream on the camera
MJPEG
Tested successfully using:
- ZM 1.28.1, FW 2.420.AC00.11.R
Camera Settings Make sure this stream is enabled on the camera! General Settings Source Type: Remote Source Settings Remote Protocol: HTTP Remote Method: Simple or Regexp both seem to work Remote Host Name: [username]:[password]@[deviceIP] Source Path: /cgi-bin/mjpg/video.cgi?channel=0&subtype=1
PTZ Controls
(Confirmed working, not yet implemented in ZM)
Right:/cgi-bin/ptz.cgi?action=start&code=Right&channel=0&arg1=1&arg2=1&arg3=0 Left:/cgi-bin/ptz.cgi?action=start&code=Left&channel=0&arg1=1&arg2=1&arg3=0 Up:/cgi-bin/ptz.cgi?action=start&code=Up&channel=0&arg1=1&arg2=1&arg3=0 Down:/cgi-bin/ptz.cgi?action=start&code=Down&channel=0&arg1=1&arg2=1&arg3=0 Up-right:/cgi-bin/ptz.cgi?action=start&code=RightUp&channel=0&arg1=1&arg2=1&arg3=0 Up-left:/cgi-bin/ptz.cgi?action=start&code=LeftUp&channel=0&arg1=1&arg2=1&arg3=0 Down-right:/cgi-bin/ptz.cgi?action=start&code=RightDown&channel=0&arg1=1&arg2=1&arg3=0 Down-left:/cgi-bin/ptz.cgi?action=start&code=LeftDown&channel=0&arg1=1&arg2=1&arg3=0 Wide:/cgi-bin/ptz.cgi?action=start&code=ZoomWide&channel=0&arg1=1&arg2=1&arg3=0 Tight:/cgi-bin/ptz.cgi?action=start&code=ZoomTele&channel=0&arg1=1&arg2=1&arg3=0 Focus-in:/cgi-bin/ptz.cgi?action=start&code=FocusNear&channel=0&arg1=1&arg2=1&arg3=0 Focus-out:/cgi-bin/ptz.cgi?action=start&code=FocusFar&channel=0&arg1=1&arg2=1&arg3=0 Stop:/cgi-bin/ptz.cgi?action=stop&code=Right&channel=0&arg1=0&arg2=0&arg3=0&arg4=0
ZoneMinder 1.31.44
RTSP
Tested successfully using:
General Settings Source Type: Ffmpeg Source Settings Source Path: rtsp://[username]:[password]@[deviceIP]:[RSTP Port]/cam/realmonitor?channel=1&subtype=0
- 554 is the default RSTP Port
Method: TCP Capture Width and Height: set to match the stream (1280x720)
IP2M-723W
A 960P outdoor bullet camera with IR illuminators; available in either wireless (W) or PoE.
ZoneMinder 1.30.0
Tested successfully using:
- ZM 1.30.0 and firmware "2.400.AC02.15.R, Build Date: 2017-07-31"
General Settings SourceType: ffmpeg Source Settings Source Path: For Primary Stream: rtsp://user:password@IP_Address:554/cam/realmonitor?channel=1&subtype=0 For Secondary Stream: rtsp://user:password@IP_Address:554/cam/realmonitor?channel=1&subtype=1 Remote Method: RTP/RTSP Target colorspace: 32 bit Capture Width and Height: set to match the stream
ZoneMinder 1.31.44
Unknown