Difference between revisions of "ACTi"

From ZoneMinder Wiki
Jump to navigationJump to search
(I do not like the fact that you need i.e. for some admin functions, but the cameras do work well.)
 
Line 3: Line 3:


This is the setup I am using for the ACM 5611
This is the setup I am using for the ACM 5611
Source type = remote
Source type = remote
Remote Protocol = HTTP
Remote Protocol = HTTP
Remote Method = Simple
Remote Method = Simple
Remote Host Name = login:pwd@IP_address
Remote Host Name = login:pwd@IP_address
Remote Port = 80
Remote Port = 80
Remote Host Path = /cgi-bin/cmd/encoder?GET_STREAM
Remote Host Path = /cgi-bin/cmd/encoder?GET_STREAM
Remote Image Colours = 24 bit colour
Remote Image Colours = 24 bit colour
Capture Width        1280
Capture Width        1280
Capture Height        720 (also used 1024)
Capture Height        720 (also used 1024)


Those were all I set and it came right up.
Those were all I set and it came right up.


I have used this same format with other cameras of the
I have used this same format with other cameras of the
ACM family, they all worked.
ACM family, they all worked.

Revision as of 18:30, 22 July 2013

ACM 5611

This is the setup I am using for the ACM 5611

Source type = remote

Remote Protocol = HTTP

Remote Method = Simple

Remote Host Name = login:pwd@IP_address

Remote Port = 80

Remote Host Path = /cgi-bin/cmd/encoder?GET_STREAM

Remote Image Colours = 24 bit colour

Capture Width 1280

Capture Height 720 (also used 1024)


Those were all I set and it came right up.


I have used this same format with other cameras of the

ACM family, they all worked.