Difference between revisions of "ACTi"

From ZoneMinder Wiki
Jump to navigationJump to search
Line 29: Line 29:


ACM family, they all worked.
ACM family, they all worked.
== ACTi D32 ==
HTTP support buggy in the D32. Use RTSP.
Remote Method: RTP/RTSP
Remote host name: user:pass@host
Remote Host Port: 7070 (this is the default port for the factory configuration. can be changed in Network menu)
Remote Host Path: (leave empty)
Target Colorspace 24 bit color
Capture Width: (set the same as camera's config)
Capture Height: (set the same as camera's config)
Preserve Aspect Ratio: unchecked
Orientation: (set to whatever you need/like)
Deinterlacing: Disabled

Revision as of 18:09, 18 February 2014

ACM 5611

This is the setup I am using for the ACM 5611

Source type = remote

Remote Protocol = HTTP

Remote Method = Simple

Remote Host Name = login:pwd@IP_address

Remote Port = 80

Remote Host Path = /cgi-bin/cmd/encoder?GET_STREAM

Remote Image Colours = 24 bit colour

Capture Width 1280

Capture Height 720 (also used 1024)


Those were all I set and it came right up.


I have used this same format with other cameras of the

ACM family, they all worked.


ACTi D32

HTTP support buggy in the D32. Use RTSP.

Remote Method: RTP/RTSP

Remote host name: user:pass@host

Remote Host Port: 7070 (this is the default port for the factory configuration. can be changed in Network menu)

Remote Host Path: (leave empty)

Target Colorspace 24 bit color

Capture Width: (set the same as camera's config)

Capture Height: (set the same as camera's config)

Preserve Aspect Ratio: unchecked

Orientation: (set to whatever you need/like)

Deinterlacing: Disabled