== AIC250W == | |||
Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /video.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration. | Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /video.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration. | ||
AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200 | AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200 | ||
AICN747/AICN747W | |||
== AICN747/AICN747W == | |||
Same Camera as Fitivision CS-130A/CS-131A and TrendNet TV-IP410/TV-IP410W. The 'W'/CS-131A version is wireless. Note: the Trendnet cameras have no built-in IR illumination. | |||
hostname = <username>:<password>@<ip of camera> | hostname = <username>:<password>@<ip of camera> | ||
path = /cgi/jpg/image.cgi for JPEG stills, or /cgi/mjpg/mjpeg.cgi for MJPEG (MJPEG mode doesn't return the correct MIME type, and thus doesn't appear to work with ZM) | path = /cgi/jpg/image.cgi for JPEG stills, or /cgi/mjpg/mjpeg.cgi for MJPEG (MJPEG mode doesn't return the correct MIME type, and thus doesn't appear to work with ZM) | ||
PTZ | |||
PTZ module details: [http://www.zoneminder.com/forums/viewtopic.php?t=12271 SkyIPCam 7xx ZM Module and Audio dump script] | |||
[http://www.zoneminder.com/forums/viewtopic.php?t=12238 Additional info on the AirLink SkyIPCam 747W] |
Revision as of 01:04, 19 September 2008
AIC250W
Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /video.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration.
AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200
AICN747/AICN747W
Same Camera as Fitivision CS-130A/CS-131A and TrendNet TV-IP410/TV-IP410W. The 'W'/CS-131A version is wireless. Note: the Trendnet cameras have no built-in IR illumination.
hostname = <username>:<password>@<ip of camera> path = /cgi/jpg/image.cgi for JPEG stills, or /cgi/mjpg/mjpeg.cgi for MJPEG (MJPEG mode doesn't return the correct MIME type, and thus doesn't appear to work with ZM)
PTZ module details: SkyIPCam 7xx ZM Module and Audio dump script