Linksys
From ZoneMinder Wiki
Revision as of 21:35, 8 January 2013 by Tonyguards (talk | contribs)
WVC-210 PTZ
remote host path = /img/video.mjpeg
Atap Fiberglass | Tangki Fiberglass
WVC2300 / PVC2300
A few options for these cameras:
- Base hit uses still image snapshots:
- Remote Host Name: user:password@ip.ad.dr.ess
- Remote Host Path: img/snapshot.cgi?size=3&quality=1
- size=1-3 (160x120, 320x240, 640x480)
- quality=1-5(very high - very low)
- Even better solution is to use pushed jpegs:
- Remote Host Name: user:password@ip.ad.dr.ess
- Remote Host Path: img/mjpeg.jpg
- Use the web administration UI for the camera to set size, quality and framerate throttling
- Would like to use ffmpeg, however this seems to be giving problems - partial image scans etc
- Source Path: http://user:password@ip.ad.dr.ess/img/video.asf
- Seems to use size and quality settings from the administration website
- What doesnt work
- img/video.mjpeg (and other similar urls). Generally barfs on zm_remote_camera_http.cpp:134, and I cant be bothered debugging it.
- Other notes
- See NetcamMjpegStreamDumps for information from the 'motion' application (scroll down to Linksys WVC54G which gave me some hints)
WVC54GC
- Source Type: ffmpeg
- Source Path: http://##.##.##.##/img/mjpeg.cgi