ACTi

From ZoneMinder Wiki
Revision as of 18:29, 22 July 2013 by Kp4djt (talk | contribs) (I do not like the fact that you need i.e. for some admin functions, but the cameras do work well.)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

ACM 5611

This is the setup I am using for the ACM 5611 Source type = remote Remote Protocol = HTTP Remote Method = Simple Remote Host Name = login:pwd@IP_address Remote Port = 80 Remote Host Path = /cgi-bin/cmd/encoder?GET_STREAM Remote Image Colours = 24 bit colour Capture Width 1280 Capture Height 720 (also used 1024)

Those were all I set and it came right up.

I have used this same format with other cameras of the ACM family, they all worked.