PLANET
ICA-HM132, ICA-HM136, ICA-HM316
The following configuration was tested with
- ICA-HM316 (outdoor, classic statically mounted)
- ICA-HM136 (outdoor, dome type)
- ICA-HM132 (indoor, dome type).
The following configuration was tested using ZoneMinder v1.25.0 but works best using the v1.26.x release branch.
Benefits of ZoneMinder 1.26.x
With beta-release 1.26 some neat performance enhancements were introduced, speeding up things when it comes to camera provisioning during startup. For instance - running on a Debian Wheezy box it took zoneminder-1.25.0-4 up to 6 minutes to connect to all eight PLANET cameras of the above mentioned types. Such cmaeras are running RTSP/H.264 at 10-15 fps and a resolution of either 640x480 (VGA) or 800x592. Running a self-compiled version of 1.26.3 instead reduced the amount of time by factor 8 and the system itself feels way more responsive.
Troubleshooting
All cameras work fine within a fully routed environment. Though, for the sake of testing you may want to place it on a local network just to minimize the effort on troubleshooting things just in case you have to. First of all make sure your camera runs on the latest firmware.
Latest Firmware
Therefore, power the camera and log-in using the default credentials (admin/admin) and IP address 192.168.0.20 which AFAIK is the default for all PLANET products so far. You can obtain the latest firmware here (direct download for models HM132, HM136 and HM316) or here. Due to the fact that upgrading requires an ActiveX applet (yeah, I know ..) you'll have to have a Internet Explorer (7+) at hand. I usually have a virtualized windows box ready to handle that kind of proprietary stuff.
Initial configuration
Change the password of the admin user to a string <= 16 characters. As of firmware version 1.0.42 guest users do not seem to work well with RTSP as long as authentication is used. Enable authentication for the RTSP Server and enable platform-wide security as shown down below (ONVIF is truly optional).
Video Settings
You'll also need to adapt the video settings of the camera to fit your needs.
It's advisable to start with lower resolutions first to ease the pain.
Some of the tested cameras seem to overheat frequently causing artifacts to occur within the video stream. This theory is supported by the fact that it seems to happen more frequently specially when using resolutions greater than 640x480 (VGA). This renders motion detection useless since the database is trashed with false positives'. I still have to look into this further since I ain't had the chance yet to exempt ffmpeg/avconv from being the root-cause.
Monitor Set-Up
Finally log on to your ZoneMinder setup creating a new Monitor using the following settings:
Final Thoughts
As with many other IP-based CCTV cameras also PLANET uses technologies like ActiveX which were proven to be vulnerable like hell for the past decade. IP-based CCTV cameras shouldn't be operated on a plain internet link. Eavesdropping can only be prevented using a fully secured environment whereas physical access restrictions to all connecting components are in place.
Once everything's set up this is what you're going to end up with - an output stream obtained via RTSP/H.264 @ 15fps providing a resolution of 800x592.