V4L2 restore control settings

Here is a simple patch that will restore the video control settings when zm is restarted when using a v4l2 driver.


*** zm/src/zm_local_camera.cpp  2009-04-10 09:49:56.000000000 -0500
--- zm-andy/src/zm_local_camera.cpp     2009-04-17
10:55:16.000000000 -0500
*************** void LocalCamera::Initialise()
*** 489,494 ****
--- 489,499 ----
          {
              Fatal( "Failed to set video standard %d: %s", standard, strerror(errno) );
          }
+
+         Contrast(contrast);
+         Brightness(brightness);
+         Hue(hue);
+         Colour(colour);
      }
      else
  #endif // ZM_V4L2 


This patch has been submitted by "genanr" member, originally posted at http://www.zoneminder.com/forums/viewtopic.php?p=52659#52659 , and has been accepted by ZM administrator to be put into the newer SVN/ ZM updates;